Your browser doesn't support javascript.
Show: 20 | 50 | 100
Results 1 - 10 de 10
Filter
2.
Vasc Endovascular Surg ; 57(5): 520-525, 2023 Jul.
Article in English | MEDLINE | ID: covidwho-2224076

ABSTRACT

To describe a case of endovascular bailout strategy during stent-graft thrombotic complication in an endovascular procedure for complex TASC II D aortoiliac lesion. A 77-year-old patient was admitted at our institution with bilateral lower limb rest pain due to aortoiliac obstructive disease in a previous aortobifemoral bypass grafting with an asymptomatic Sars-CoV-2 infection. We planned an anatomic reconstruction of the aortoiliac segment with an unimodular bifurcated stent-graft. During the procedure, we observed a preocclusive thrombosis of the aortic portion requiring endovascular thrombectomy with vacuum assisted system followed by a successfully kissing-stent endolining. The post-operative period was uneventful and patient was discharged on the 14th post-operative day. Endovascular thrombectomy may be a helpful strategy during thrombotic complication of complex reconstructions of obstructive aortoiliac disease avoiding surgical conversion to laparotomy.


Subject(s)
COVID-19 , Endovascular Procedures , Thrombosis , Humans , Aged , Iliac Artery/diagnostic imaging , Iliac Artery/surgery , Iliac Artery/pathology , Treatment Outcome , COVID-19/complications , SARS-CoV-2 , Stents/adverse effects , Postoperative Complications/etiology , Endovascular Procedures/adverse effects , Thrombosis/diagnostic imaging , Thrombosis/etiology , Thrombosis/surgery , Blood Vessel Prosthesis/adverse effects , Retrospective Studies , Vascular Patency
4.
Int J Mol Sci ; 23(19)2022 Sep 21.
Article in English | MEDLINE | ID: covidwho-2066117

ABSTRACT

Vascular replacement is one of the most effective tools to solve cardiovascular diseases, but due to the limitations of autologous transplantation, size mismatch, etc., the blood vessels for replacement are often in short supply. The emergence of artificial blood vessels with 3D bioprinting has been expected to solve this problem. Blood vessel prosthesis plays an important role in the field of cardiovascular medical materials. However, a small-diameter blood vessel prosthesis (diameter < 6 mm) is still unable to achieve wide clinical application. In this paper, a response surface analysis was firstly utilized to obtain the relationship between the contact angle and the gelatin/sodium alginate mixed hydrogel solution at different temperatures and mass percentages. Then, the self-developed 3D bioprinter was used to obtain the optimal printing spacing under different conditions through row spacing, printing, and verifying the relationship between the contact angle and the printing thickness. Finally, the relationship between the blood vessel wall thickness and the contact angle was obtained by biofabrication with 3D bioprinting, which can also confirm the controllability of the vascular membrane thickness molding. It lays a foundation for the following study of the small caliber blood vessel printing molding experiment.


Subject(s)
Bioprinting , Blood Substitutes , Alginates , Blood Vessel Prosthesis , Gelatin , Hydrogels/pharmacology , Printing, Three-Dimensional , Tissue Engineering , Tissue Scaffolds
6.
PLoS One ; 15(6): e0233981, 2020.
Article in English | MEDLINE | ID: covidwho-1456053

ABSTRACT

We aimed to examine aneurysm hemodynamics with intra-saccular pressure measurement, and compare the effects of coiling, stenting and stent-assisted coiling in proximal segments of intracranial circulation. A cohort of 45 patients underwent elective endovascular coil embolization (with or without stent) for intracranial aneurysm at our department. Arterial pressure transducer was used for all measurements. It was attached to proximal end of the microcatheter. Measurements were taken in the parent artery before and after embolization, at the aneurysm dome before embolization, after stent implantation, and after embolization. Stent-assisted coiling was performed with 4 different stents: LVIS and LVIS Jr (Microvention, Tustin, CA, USA), Leo (Balt, Montmorency, France), Barrel VRD (Medtronic/ Covidien, Irvine, CA, USA). Presence of the stent showed significant reverse correlation with intra-aneurysmal pressure-both systolic and diastolic-after its implantation (r = -0.70 and r = -0.75, respectively), which was further supported by correlations with stent cell size-r = 0.72 and r = 0.71, respectively (P<0.05). Stent implantation resulted in significant decrease in diastolic intra-aneurysmal pressure (p = 0.046). Systolic or mean intra-aneurysmal pressure did not differ significantly. Embolization did not significantly change the intra-aneurysmal pressure in matched pairs, regardless of the use of stent (p>0.05). In conclusion, low-profile braided stents show a potential to divert blood flow, there was significant decrease in diastolic pressure after stent placement. Flow-diverting properties were related to stent porosity. Coiling does not significantly change the intra-aneurysmal pressure, regardless of packing density.


Subject(s)
Blood Pressure , Intracranial Aneurysm/physiopathology , Stents , Aged , Arterial Pressure , Blood Circulation , Blood Vessel Prosthesis , Brain/blood supply , Brain/physiopathology , Embolization, Therapeutic , Female , Hemodynamics , Humans , Intracranial Aneurysm/therapy , Male , Middle Aged
7.
Neurosurgery ; 87(3): 516-522, 2020 09 01.
Article in English | MEDLINE | ID: covidwho-1455333

ABSTRACT

BACKGROUND: Pipeline embolization device (PED; Medtronic) and stent-assisted coiling (SAC) are established modalities for treatment of intracranial aneurysms. OBJECTIVE: To comparatively assess the efficacy of these techniques. METHODS: We conducted a retrospective analysis of patients with aneurysms treated at our institution with either PED from 2013 to 2017 or SAC from 2009 to 2015. All large (>10 mm), ruptured, fusiform, anterior communicating artery, posterior circulation aneurysms, and patients with no available follow-up imaging were eliminated before running the propensity score matching (PSM). Patients were matched using nearest neighbor controlling for: age, gender, smoking, exact location, maximal diameter, and presence of multiple aneurysms. Total hospital costs for equipment and implants were calculated from procedure product and hospital billing records, and compared between the propensity-matched pairs. RESULTS: Out of 165 patients harboring 202 aneurysms; 170 (84.2%) were treated with the PED, and 32 (15.8%) were treated using SAC. PSM resulted in 23 matched pairs; with significantly longer follow up in the SAC group (mean 29.8 vs 14.1 mo; P = .0002). Complete occlusion rates were not different (82.6 vs 87%; P = .68), with no difference between the groups for modified Rankin Scale on last clinical follow-up, procedural complications or retreatment rates. Average total costs calculated from the hospital records, including equipment and implants, were not different between propensity-score matched pairs (P = .48). CONCLUSION: PED placement and SAC offer equally efficacious occlusion rates, functional outcomes, procedural complication rates, and cost profiles for small unruptured anterior circulation saccular aneurysms which do not involve the anterior communicating artery.


Subject(s)
Blood Vessel Prosthesis , Embolization, Therapeutic/instrumentation , Endovascular Procedures/instrumentation , Intracranial Aneurysm/therapy , Stents , Adult , Aged , Embolization, Therapeutic/methods , Endovascular Procedures/methods , Female , Humans , Male , Middle Aged , Propensity Score , Retrospective Studies , Treatment Outcome
8.
Ann Vasc Surg ; 73: 557-560, 2021 May.
Article in English | MEDLINE | ID: covidwho-1312937

ABSTRACT

Aneurysms and occlusive pathologies of the aorta are frequently associated with atherosclerosis; however, thoracoabdominal aortic aneurysm accompanied by Leriche syndrome is an extremely rare condition with challenging treatment strategy and without established surgical treatment protocols. In this report, we present our treatment strategy in a 64-year-old male patient with ischemic heart disease and type 5 thoracoabdominal aortic aneurysm accompanied by Leriche syndrome.


Subject(s)
Aortic Aneurysm, Thoracic/surgery , Blood Vessel Prosthesis Implantation , Coronary Artery Bypass , Coronary Artery Disease/surgery , Leriche Syndrome/surgery , Saphenous Vein/transplantation , Aortic Aneurysm, Thoracic/complications , Aortic Aneurysm, Thoracic/diagnostic imaging , Blood Vessel Prosthesis , Blood Vessel Prosthesis Implantation/instrumentation , COVID-19/complications , COVID-19/diagnosis , Coronary Artery Disease/complications , Coronary Artery Disease/diagnostic imaging , Fatal Outcome , Humans , Leriche Syndrome/complications , Leriche Syndrome/diagnostic imaging , Male , Middle Aged , Polyethylene Terephthalates , Treatment Outcome
9.
Medicina (Kaunas) ; 57(6)2021 Jun 14.
Article in English | MEDLINE | ID: covidwho-1270080

ABSTRACT

The aim of this paper is to share our experience in managing a patient with Klebsiella pneumoniae mycotic abdominal aortic aneurysm who was also infected with COVID-19. A 69-year-old male was transferred to our hospital for the management of an infra-renal mycotic abdominal aortic aneurysm. During his hospital course, the patient contracted severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2). He was intubated due to respiratory distress. Over a short period, his mycotic aneurysm increased in size from 2.5 cm to 3.9 cm. An emergency repair of his expanding aneurysm was achieved using our previously described protocol of coating endovascular stents with rifampin. The patient was managed with a rifampin-coated endovascular stent graft without any major complications. Postoperatively, the patient did not demonstrate any neurological deficits nor any vascular compromise. He remained afebrile during his postoperative course and was extubated sometime thereafter. He was then transferred to the ward for additional monitoring prior to his discharge to a rehab hospital while being on long-term antibiotics. During his hospital stay, he was monitored with serial ultrasounds to ensure the absence of abscess formation, aortic aneurysm growth or graft endoleak. At 6 weeks after stent graft placement, he underwent a CT scan, which showed a patent stent graft, with a residual sac size of 2.5 cm without any evidence of abscess or endoleak. Over a follow-up period of 180 days, the patient remained asymptomatic while remaining on long-term antibiotics. Thus, in patients whose surgical risk is prohibitive, endovascular stent grafts can be used as a bridge to definitive surgical management.


Subject(s)
Aneurysm, Infected , Aortic Aneurysm, Abdominal , Blood Vessel Prosthesis Implantation , COVID-19 , Endovascular Procedures , Aged , Aneurysm, Infected/surgery , Aortic Aneurysm, Abdominal/surgery , Blood Vessel Prosthesis , Humans , Male , SARS-CoV-2 , Stents , Treatment Outcome
10.
Ann Vasc Surg ; 66: 8-10, 2020 Jul.
Article in English | MEDLINE | ID: covidwho-133306

ABSTRACT

BACKGROUND: COVID-19 infection has been reported to be related with an increased risk of thrombotic complications because of the hypercoagulability state and inflammation. At the moment, no reports are available regarding thrombosis of prosthetic vascular grafts. We present the case of a patient with COVID-19-related pneumonia, who suffered from the acute thrombosis of a previously implanted aortic graft. METHODS AND RESULTS: A 67-year-old male patient, who had undergone open repair of an abdominal aortic aneurysm with a bifurcated graft 6 years before, was admitted to the emergency department with high fever for a week without cough or dyspnea. Thoracic ultrasound showed signs of bilateral interstitial pneumonia, and the Sars-Cov-2 swab was positive. Antiretroviral therapy and prophylactic low molecular weight heparin treatment were initiated. Owing to the progressive impairment of the respiratory function, the patient was intubated after eight days from the admission, the day after he showed signs of bilateral acute limb ischemia. A duplex ultrasound demonstrated the complete thrombosis of the aortic graft without flow at the femoral level. An urgent angio-computed tomography scan for revascularization purpose was requested, but the patient died on the arrival in the radiological suite. CONCLUSIONS: Acute thrombosis of vascular prosthetic grafts is a possible, catastrophic complication of COVID-19 infection. In COVID-19 patients with prosthetic graft, an aggressive antithrombotic treatment could be considered to prevent such an event.


Subject(s)
Aortic Aneurysm, Abdominal/surgery , Betacoronavirus , Blood Vessel Prosthesis/adverse effects , Coronavirus Infections/complications , Graft Occlusion, Vascular/etiology , Pneumonia, Viral/etiology , Aged , Aortic Aneurysm, Abdominal/complications , Blood Vessel Prosthesis Implantation/adverse effects , COVID-19 , Humans , Male , Pandemics , Pneumonia, Viral/complications , SARS-CoV-2
SELECTION OF CITATIONS
SEARCH DETAIL